Brooks Australia PRODUCT DATA SHEET Smoke Alarm EIPFS3105TYCH - Photoelectric 9 Volt Primary Lithium Power with Hush and Interconnect
• Lithium 10 year battery to provide long lasting life
• No changing of battery required - soldered into the printed circuit board
• High performance optical chamber with integral insect screen
• Advanced suppression and calibration technology
• Simple 2 core wiring for interconnection
• Interconnect up to 20 other TY series alarms
• Accredited to AS3786 - ActivFire Listed
Applications
The EIPFS3105TYCH is easily installed and comes supplied with all necessary
The non removable battery is designed to
screw fixings. Unlike its 230 volt equivalent
batteries to replace. This makes this the
licenced electrician, a significant cost
The EIPFS3105TYCH is particularly useful
battery removal by a tenant is of concern.
Ideal for rental properties – no battery
silence nuisance alarms from cooking etc, if they occur, for 10 minutes.
Product Description
The EIPFS3105TYCH has an advanced high performance optical chamber fitted
with integral insect screens to reduce the
10 year lithium battery to provide a long
lasting life. What makes the EIPFS3105TYCH different from other “so called” 10 year devices? - Its lithium
Optical smoke alarms use the light scatter
battery is integrated into the alarm printed
principle to detect smoke particles entering
circuit board not just a plug in battery with
Photoelectric (Optical) smoke alarms are
addition the battery is of a type not used in
other household appliances; therefore the
temptation to remove the battery has itself
smouldering bed linen, plastics, and fused
significantly increases the audible warning provided and the chances of waking
Visibly dense smoke, which also contains
toxic fumes, impairs the occupant’s ability
warning throughout the building, no lost
to see and make their way to an exit. The
use of photoelectric smoke detection in all
The EIPFS3105TYCH has built in circuitry
to aid suppression of RF interference to further reduce the chances of false alarms;
interconnect up to twenty TY series alarms
contacts to prevent sounder failure due to
to allow all alarms to sound if just one of
pressure fit contact corrosion, an identified
Operation
The test button will flash red every 40 seconds to show that the detector has
The red indicator will flash rapidly to show an alarm condition for the smoke detector
The "Test/Hush" button will either silence false alarms or perform a unit self test
In "Test" mode the alarm will perform a self test and sound the horn
Interconnect up to 20 other alarms (EIPFS100TYC and EIPFS3105TYCH). When
interconnected an alarm in one sensor will trigger all other interconnected alarms
within one second (only the triggered alarm will flash a red indicator). Interconnection
helps ensure that the warning will be heard throughout the Dwelling.
At the end of its service life (10 years+) the EIPFS3105TYCH will emit a beep every
40 seconds to indicate that the battery is depleted and the unit needs replacing.
For further details see the operator and installer manuals BROOKS AUSTRALIA National Call – 1300 78 FIRE Technical Specification
Optical, uses light scatter from smoke (Note: Sensing chamber meets the 25mm stand-off installation requirements of AS1670.1 and AS1670.6) Ambient Light:
Chamber housing and compensation overcomes possible
Sensitivity:
Complies with AS 3786 (Nominal 10%Obs/m)
Airspeed:
Essentially immune to the effects of airspeed
Test Facility:
Simulates the effect of smoke and checks electronics and
horn Automatic Self-Test:
Smoke chamber is tested every 40 seconds and unit beeps
(without LED flash) if the sensor is de-graded
Insect Screen:
1mm diameter stainless steel mesh mitigates insect and
Integrated 9 Volt 10 year lithium battery
Power ‘ON’ Indicator: Low Battery Warning:
Beeps every 40 second when the stand-by battery reaches it depletion threshold
Alarm Sounder: Alarm Sounder Connection: Piezo contacts are soldered to prevent failure due to contact
corrosion over time – enhanced reliability.
Alarm Sounder Output: Alarm Status Indicator:
Red LED flashes every second on device sensing fire.
Temperature Range: Humidity Range: Conformal Coating:
Wax coating applied to PCB to mitigate the effects of
contamination Interconnection:
Up to 20 TY series smoke or heat alarms may be
(NOTE: Do not interconnect to other manufacturer’s devices)
Enclosure Material: Dimensions: Weight: 281g Warranty: Approvals: Australian - Certified to AS3786 CSIRO afp 1692
International - Kitemarked to BS5446-1:2000, CE Approved
Specifications subject to change Accessories BAALOC – Alarm locator module BROOKS AUSTRALIA National Call – 1300 78 FIRE
Catatonic Schizophrenia Causes Symptoms Information with Treatment by: Juliet Cohen Published by Schizophrenia results from problems with early brain development. The way brain cellscommunicate with each other through nerve pathways. Complete lack of expressed emotion issometimes seen, as is an apparent indifference, anhedonia (the lack of pleasure ), and avolition (alack of motivatio
Exploring the molecular basis of combination drugs using ToxWiz For further information: Email: [email protected] Tel: +44 1223 703 137 Fax: +44 1223 858 794 Drug combinations represent intriguing possibilities for new therapies. The basic principle is that two active compounds can lead to effects that are more than the sum of their parts, possibly by simultaneously blocking